Research Article
Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet
Table 10
Effect of lacing wire damage induced mistuning (for λ = 0.5) on natural frequencies (lacing wire at 2/3rd of blade span).
| Mode | Submode | values | = 0 | = 0.2 | = 0.4 | = 0.6 | = 0.8 | = 1.0 |
| 1 | I | 1.8751 | 1.8751 | 1.8751 | 1.8751 | 1.8751 | 1.8751 | II | 1.9396 | 1.9324 | 1.9227 | 1.9100 | 1.8941 | 1.8751 | III | 2.0511 | 2.0364 | 2.0235 | 2.0128 | 2.0043 | 1.9978 |
| 2 | I | 4.6941 | 4.6941 | 4.6941 | 4.6941 | 4.6941 | 4.6941 | II | 4.6967 | 4.6964 | 4.6960 | 4.6955 | 4.6948 | 4.6941 | III | 4.7019 | 4.7012 | 4.7005 | 4.7000 | 4.6996 | 4.6993 |
| 3 | I | 7.8548 | 7.8548 | 7.8548 | 7.8548 | 7.8548 | 7.8548 | II | 7.8560 | 7.8559 | 7.8557 | 7.8554 | 7.8551 | 7.8548 | III | 7.8586 | 7.8583 | 7.8579 | 7.8577 | 7.8575 | 7.8573 |
|
|