Research Article

Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet

Table 10

Effect of lacing wire damage induced mistuning (for λ = 0.5) on natural frequencies (lacing wire at 2/3rd of blade span).

ModeSubmode values
= 0 = 0.2 = 0.4 = 0.6 = 0.8 = 1.0

1I1.87511.87511.87511.87511.87511.8751
II1.93961.93241.92271.91001.89411.8751
III2.05112.03642.02352.01282.00431.9978

2I4.69414.69414.69414.69414.69414.6941
II4.69674.69644.69604.69554.69484.6941
III4.70194.70124.70054.70004.69964.6993

3I7.85487.85487.85487.85487.85487.8548
II7.85607.85597.85577.85547.85517.8548
III7.85867.85837.85797.85777.85757.8573