Research Article

Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet

Table 11

Effect of lacing wire damage induced mistuning (for λ = 1) on natural frequencies (lacing wire at 2/3rd of blade span).

ModeSubmode values
= 0 = 0.2 = 0.4 = 0.6 = 0.8 = 1.0

1I1.87511.87511.87511.87511.87511.8751
II1.99781.98471.96681.94301.91251.8751
III2.18842.16462.14332.12542.11112.1002

2I4.69414.69414.69414.69414.69414.6941
II4.69934.69874.69794.69684.69564.6941
III4.70984.70834.70704.70604.70524.7045

3I7.85487.85487.85487.85487.85487.8548
II7.85737.85707.85667.85617.85557.8548
III7.86257.86177.86117.86067.86027.8599