Research Article

Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet

Table 12

Natural frequencies ( values) of the tuned blade packet with varying stiffness ratios (lacing wire at mid span).

ModeSubmode = 0.1 = 0.25 = 0.5 = 1.0

1I1.87511.87511.87511.8751
II1.88031.88801.90061.9249
III1.89061.91291.94792.0109

2I4.69414.69414.69414.6941
II4.69564.69784.70154.7019
III4.69854.70524.71624.7275

3I7.85487.85487.85487.8548
II7.85487.85487.85487.8548
III7.85487.85487.85487.8548