Research Article

Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet

Table 13

Effect of lacing wire damage induced mistuning (for λ = 0.1) on natural frequencies (lacing wire at mid span).

ModeSubmode values
= 0 = 0.2 = 0.4 = 0.6 = 0.8 = 1.0

1I1.87511.87511.87511.87511.87511.8751
II1.88031.87971.87891.87791.87661.8751
III1.89061.88911.88791.88691.88611.8855

2I4.69414.69414.69414.69414.69414.6941
II4.69564.69544.69524.69494.69454.6941
III4.69854.69814.69774.69754.69724.6970

3I7.85487.85487.85487.85487.85487.8548
II7.85487.85487.85487.85487.85487.8548
III7.85487.85487.85487.85487.85487.8548