Research Article

Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet

Table 14

Effect of lacing wire damage induced mistuning (for λ = 0.25) on natural frequencies (lacing wire at mid span).

ModeSubmode values
= 0 = 0.2 = 0.4 = 0.6 = 0.8 = 1.0

1I1.87511.87511.87511.87511.87511.8751
II1.88801.88661.88461.88201.87881.8751
III1.91291.90951.90651.90401.90211.9006

2I4.69414.69414.69414.69414.69414.6941
II4.69784.69744.69684.69604.69514.6941
III4.70524.70414.70324.70254.70194.7015

3I7.85487.85487.85487.85487.85487.8548
II7.85487.85487.85487.85487.85487.8548
III7.85487.85487.85487.85487.85487.8548