Comparison of natural frequencies obtained analytically and FEM.

ModeSubmodeFrequency in Hz (analytical)Frequency in Hz
(FEM)
% error

1I72.5273.150.87
II75.9476.560.80
III82.3282.900.71

2I454.45458.040.78
II455.00458.600.78
III456.14459.730.78

3I1272.451284.900.97
II1272.631285.100.97
III1273.061285.500.97

The % error in the results of natural frequencies in the submodes of three bending modes of vibration obtained with both methods is less than 1%.