Effect of mistuning due to lacing wire damage (for = 0.1) on natural frequencies.

ModeSubmode values
= 0 = 0.2 = 0.4 = 0.6 = 0.8 = 1.0

1I1.87511.87511.87511.87511.87511.8751
II1.91891.91401.90731.89871.88791.8751
III1.99781.98721.97801.97031.96421.9597

2I4.69414.69414.69414.69414.69414.6941
II4.69704.69674.69624.69564.69494.6941
III4.70284.70204.70134.70074.70024.6999

3I7.85487.85487.85487.85487.85487.8548
II7.85547.85537.85527.85517.85497.8548
III7.85667.85647.85637.85627.85617.8560