Research Article

Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet

Table 4

Effect of mistuning due to lacing wire damage (for = 0.25) on natural frequencies.

ModeSubmode values
= 0 = 0.2 = 0.4 = 0.6 = 0.8 = 1.0

1I1.87511.87511.87511.87511.87511.8751
II1.97901.96781.95261.93231.90651.8751
III2.14482.12392.10522.08952.07712.0675

2I4.69414.69414.69414.69414.69414.6941
II4.70144.70054.69944.69794.69624.6941
III4.71604.71394.71214.71074.70954.7087

3I7.85487.85487.85487.85487.85487.8548
II7.85637.85617.85597.85567.85527.8548
III7.85947.85907.85867.85837.85807.8579