Research Article
Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet
Table 7
Natural frequencies (
values) of the tuned blade packet with varying stiffness ratios (lacing wire at 2/3rd of blade span).
| Mode | Submode | = 0.1 | = 0.25 | = 0.5 | = 1.0 |
| 1 | I | 1.8751 | 1.8751 | 1.8751 | 1.8751 | II | 1.8886 | 1.9082 | 1.9396 | 1.9978 | III | 1.9146 | 1.9694 | 2.0511 | 2.1884 |
| 2 | I | 4.6941 | 4.6941 | 4.6941 | 4.6941 | II | 4.6946 | 4.6954 | 4.6967 | 4.6993 | III | 4.6957 | 4.6980 | 4.7019 | 4.7065 |
| 3 | I | 7.8548 | 7.8548 | 7.8548 | 7.8548 | II | 7.8550 | 7.8554 | 7.8560 | 7.8573 | III | 7.8555 | 7.8567 | 7.8586 | 7.8625 |
|
|