Research Article

Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet

Table 8

Effect of lacing wire damage induced mistuning (for λ = 0.1) on natural frequencies of the blade packet (lacing wire at 2/3rd of blade span).

ModeSubmode values
= 0 = 0.2 = 0.4 = 0.6 = 0.8 = 1.0

1I1.87511.87511.87511.87511.87511.8751
II1.88861.88701.88491.88231.87901.8751
III1.91461.91101.90781.90531.90321.9017

2I4.69414.69414.69414.69414.69414.6941
II4.69464.69464.69454.69444.69424.6941
III4.69574.69554.69544.69534.69524.6951

3I7.85487.85487.85487.85487.85487.8548
II7.85507.85507.85497.85497.85487.8548
III7.85557.85557.85547.85537.85537.8553