Research Article

Analytical and Numerical Investigation of Lacing Wire Damage Induced Mistuning in Turbine Blade Packet

Table 9

Effect of lacing wire damage induced mistuning (for λ = 0.25) on natural frequencies (lacing wire at 2/3rd of blade span).

ModeSubmode values
= 0 = 0.2 = 0.4 = 0.6 = 0.8 = 1.0

1I1.87511.87511.87511.87511.87511.8751
II1.90821.90441.89941.89281.88471.8751
III1.96941.96111.95381.94781.94311.9396

2I4.69414.69414.69414.69414.69414.6941
II4.69544.69524.69504.69484.69454.6941
III4.69804.69764.69734.69704.69684.6967

3I7.85487.85487.85487.85487.85487.8548
II7.85547.85537.85527.85517.85497.8548
III7.85677.85657.85637.85627.85617.8560