Comparison of results.

Sl. numberNondimensional Natural FrequencyNondimensional mode shape differenceHybrid fuzzy controllerExperimental

10.9350.9570.9520.2620.2260.3090.1230.2020.1250.200
20.9240.9550.950.3780.3150.3780.1270.3050.1250.300
30.9090.9430.9480.1750.0340.0820.1220.3960.1250.400
40.9410.9620.9550.141−0.0820.1890.2480.1980.2500.200
50.9190.9610.9390.012−0.8050.2420.2460.2970.2500.300
60.9320.9570.9370.1780.0590.3720.2520.4030.250.400
70.9370.950.9540.0650.2390.3940.3710.2040.3750.200
80.9290.9480.9510.0780.2910.3760.3740.2990.3750.300
90.9310.9420.949−0.0350.2960.3900.3790.4050.3750.400