Research Article

Mechanical Performance Investigation of a Flat-Roof and Four-Slope Folded Plate Structure

Table 1

Test displacement values of the top plate of the folded plate structure.

Model (mm)Measuring pointLoad value (N)
50100150200250300

3Left side−0.0099−0.0199−0.0298−0.0398−0.0498−0.0597
Right side−0.0099−0.0202−0.0304−0.0404−0.0504−0.0602
Mean value−0.0099−0.0201−0.0301−0.0401−0.0501−0.0600

4 Left side−0.0069−0.0129−0.0188−0.0248−0.0308−0.0356
Right side−0.0069−0.0135−0.0194−0.0256−0.0316−0.0363
Mean value−0.0069−0.0132−0.0191−0.0252−0.0314−0.0360