Research Article
Enhanced Thermoelectric Efficiency of Cement-Based Materials with Cuprous Oxide for Sustainable Buildings
Table 4
The Seebeck coefficient, electrical conductivity, thermal conductivity, and average ZT of different series of cement composites.
| Series | Seebeck coefficient (μV/K) | Electrical conductivity (10−4 S/m) | Thermal conductivity (W/(m·K)) | ZT |
| M0 | −0.3 ± 0.04 | 2.31 ± 0.07 | 0.60 ± 0.010 | 1.09 × 10−14 | M5C2 | 364 ± 15 | 2.54 ± 0.11 | 0.63 ± 0.007 | 1.96 × 10−8 | M5C4 | 670 ± 17 | 2.59 ± 0.10 | 0.67 ± 0.009 | 5.48 × 10−8 | M5C5 | 3966 ± 54 | 2.68 ± 0.12 | 0.69 ± 0.007 | 1.93 × 10−6 |
|
|