Research Article

Semicontinuous Blending of Pharmaceutical Ingredients and the Impact of Process Parameters on the Blending Performance of an Integrated Feeder Blender Operating Semicontinuously

Table 4

Comparison of output blend from batch blending, continuous blending, and semicontinuous blending.

Batch blendingContinuous blendingSemicontinuous blending

Bulk density (g/ml)0.367 (SD 0.017)0.358 (SD 0.022)0.373 (SD 0.016)
Tap density (g/ml)0.462 (SD 0.012)0.451 (SD 0.013)0.470 (SD 0.012)
Carr index20.51520.62220.582
Hausner’S ratio1.2581.2601.259