Summary of the recently published SAR ADC performance parameters in 180 nm process.

ReferenceSupply (v)Power (w)Area (mm2)Fs (S/s)Resolution (dB)ENOB (dB)SNDR (dB)SFDR (dB)DNL (LSB)INL (LSB)(fJ/conv.-step)

[24]0.8647 n0.2320 K1210.4864850.49/−0.410.47/−0.4222
[87]3.3477.2 μ150 K1411.370.2882.911.4/−0.251.1/−2.1
[98]112.2 μ0.055
[2]1.52.7 μ0.05250 K1266.51770.83/−0.260.88/−0.6130.5
[6]1.81.9 μ0.08610 K1312.630.6
[63]1.80.28 μ0.172 K1110.1462.874.40.1/−0.60.35/−0.84120
[39]0.642 n20 K109.458.273.70.572/−0.5690.533/−0.4223.11
[19]0.513.99 μ1 M107.6961.9668.540.9/−0.821.06/−1.31
[33]1.590.15 μ1 M141167.90.4/−0.21/−1
[8]1.2310 n13.56 M1211.876.40.5/−0.680.62/−0.56
[29]1.276.88 μ0.1920 M54.7430.340max −1Less than 1.1144
[67]1.80.26 μ25 K87.150.10.45–0.7−0.97.58
[80]0.643.7 n0.1035100 K109.5559.378.20.28/−0.240.67/−0.410.58
[47]1A/0.5D4.1 n0.02491 K109.7360.369.80.31/−0.30.32/−0.24.1
[53]1.8490 μ1 M10.7666.5478.420.72/−0.550.92/−0.7857.2
[16]1.8/0.96.98 μ200 K98.351.956.2111
[11]0.75250 n0.1210 K119.7660.5720.6/−0.370.94/−0.8928.8
[66]1.290 μ0.163.125 M107.4146.375.64/−14.76/−4.24169000
[5]1306 n0.0540 K109.0256.1670.56/−0.691.14/−0.714.3
[10]1.878.8 μ50 M10
[12]0.568 n0.14410 K109.357.861.60.41/−0.450.57/−0.4810.8
[65]1.8A/0.9D9.7 μ0.3550 K1268.688.4
[52]1.85.18 m100 M1312.1576.10.37/−0.440.56/−0.459.65
[83]1.83.8 m0.2310 M108.553.160.92.8/−13.7/−3.6