Case Report

A Cone Bean Computer Tomography Investigation of the Newly Formed Mandibular Anterior Ridge following the Treatment of an Extended Comminuted Fracture: A 12-Year Follow-Up

Figure 3

(a) OPT: postoperative treatment of the comminuted fracture with two osteosynthesis plates and two lag screws. (b) OPT: postoperative restoration of the switching gap with an adhesive bridge. (c) OPT: removal of an osteosynthesis plate at 10 months after the accident. (d) OPT: insertion of three Ankylos® implants with the dimensions  mm. (e) OPT: after inserting the three Ankylos® implants, the switching gap was closed again with an adhesive bridge. (f) OPT: definitive restoration of the implants with a metal-ceramic bridge in the anterior part of the mandible.
(a)
(b)
(c)
(d)
(e)
(f)