Research Article

Evaluation of the Water Quality Status and Pollution Load Carrying Capacity of Way Umpu River, Way Kanan District, Lampung Province, Indonesia, Based on Land Use

Table 2

Water quality measurement results.

No.ParametersUnitStandard Class IIISampling location
ST-1ST-2ST-3ST-4ST-5ST-6ST-7

1Air Temp°C27 ± 029 ± 027 ± 029 ± 029 ± 027 ± 028.5 ± 0
2Water Temp°C27.9 ± 0.127.6 ± 0.127.9 ± 0.329.2 ± 0.328.1 ± 0.127.9 ± 0.127.7 ± 0.1
3TDSmg/L1,00028 ± 1.424.5 ± 1.128.6 ± 1.242.1 ± 1.224 ± 2.831.2 ± 0.226.0 ± 0.6
4TSSmg/L1007.4 ± 0.412 ± 1.011.2 ± 0.8235 ± 2.811.2 ± 1.61 0.8 ± 0.412.0 ± 0.7
5ColorPt-Co10038.7 ± 2.840.5 ± 1.756.7 ± 1.5181 ± 7.136.9 ± 2.142.3 ± 2.841.0 ± 1.3
6TurbidityNTU4.9 ± 0.65.8 ± 0.16.8 ± 070.6 ± 6.46.3 ± 0.19.4 ± 0.46.4 ± 0.2
7pH6–97.8 ± 0.17.4 ± 0.17.8 ± 0.086.7 ± 0.37.5 ± 0.27.7 ± 0.27.6 ± 0.1
8Salinityo/oo0000000 ± 0
9BODmg/L62 ± 0.32.2 ± 0.33.6 ± 0.079.7 ± 0,22.4 ± 0.32.0 ± 0.12.2 ± 0.2
10CODmg/L401.9 ± 0.14.4 ± 0.47.9 ± 0.322.4 ± 1.65.0 ± 0.14.1 ± 0.24.0 ± 0.4
11DOmg/L33.9 ± 0.63.8 ± 0.14.1 ± 0.0033.9 ± 0.63.8 ± 0.23.7 ± 0.33.8 ± 0.2
12P (PO4)mg/L10.4 ± 0.010.5 ± 0.040.6 ± 0.0030.3 ± 0.020.4 ± 0060.4 ± 0.040.4 ± 0.1
13N(NO3)mg/L200.5 ± 0.010.7 ± 0.060.7 ± 0.00041.7 ± 0.040.8 ± 0.031.5 ± 0.40.7 ± 0.01
14Cdmg/L0.010.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 0
15Crmg/L0.050.0003 ± 00.0003 ± 00.0003 ± 00.0003 ± 00.0003 ± 00.0003 ± 00.0003 ± 0
16Cumg/L0.020.002 ± 0.0010.003 ± 0.0010.004 ± 0.00010.002 ± 0.00030.001 ± 0.00040.002 ± 0.0010.003 ± 0.0009
17Pbmg/L0.030.001 ± 0.0010.001 ± 0.00010.0009 ± 0.000040.001 ± 0.00010.0007 ± 0.00010.0008 ± 0.0010.001 ± 0.0002
18Hgmg/L0.0020.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 00.0002 ± 0
19N (NO2)mg/L0.060.002 ± 0.0020.003 ± 0.0010.002 ± 0.00010.008 ± 0.0010.002 ± 0.0010.007 ± 0.0030.003 ± 0.0003
20Cnmg/L0.020.01 ± 00.01 ± 00.01 ± 00.01 ± 00.01 ± 00.01 ± 00.01 ± 0
22Fecal coliformMPN/100 mL2,0007.2 ± 0.39.4 ± 1.07.2 ± 0.111 ± 1.47.4 ± 1.47.2 ± 0.38.8 ± 0.6
23Total coliformMPN/100 mL10,0007.2 ± 0.39.4 ± 1.011 ± 1.411 ± 1.47.4 ± 1.47.2 ± 0.28.8 ± 0.7

Standard: water body for Class III purposes according to Local Regulation of Lampung Province [20]. ST-7∗: The results obtained are based on the calculation of the pollution load capacity according to Kepmen LH No. 110 of 2003 [17].