Research Article
Size-Dependent Chlorinated Nitrogen-Doped Carbon Nanotubes: Their Use as Electrochemical Detectors for Catechol and Resorcinol
Table 1
Diameter analysis of purified NCNTs generated from CH3CN feeds containing various concentrations of DCB.
| CH3CN : DCB volume ratio | Outer diameter range (nm) | Average outer diameter (nm) | Average inner diameter (nm) | Number of structures counted | Reagent volume used (mL) |
| 66.7 : 33.3 (2 : 1) | 75–176 | 115 ± 34.2 | 22 | >300 | 4 | 33.3 : 66.7 (1 : 2) | 30–90 | 64 ± 15.5 | 14 | >300 | 3 |
|
|