Research Article
Estimation of the Uncertainty due to Each Step of Simulating the Photovoltaic Conversion under Real Operating Conditions
Table 4
Equipment and sensors used for all the presented measurements.
| Param. | Manufact. | Model | Std | Accuracy | Meas. uncert. |
| PV module level measurements | | Agilent | 6060B | IEC 60891 | Electronic load: Voltmeter: Ammeter: | | | TC | 578-093 Class A | IEC 60751 | [-20 °C; +100 C]: C at 0 C | C C | | Hukseflux Tektronix | SR01 2nd class 3706A | ISO 9060 | in hourly totals DC voltmeter: | |
| Atmospheric in situ measurements (SIRTA) | GHI | Kipp & Zonen | CM22 | ISO | Daily uncertainty | | | 2ry std | 9060 | | | BNI | Kipp & Zonen | CHP1 | ISO | Daily uncertainty | | | 2ry std | 9060 | | | | Guilcor | Pt100 | IEC | [-100 °C; +100 C]: C | C | | Class B | 60751 | at 0 C | | WS | Vector | A100R | | [0.3 m/s; 10 m/s]: | | | | | | |
| Atmospheric measurements from nearby weather station (ORLY) | GHI | Kipp & Zonen | CM6B | ISO | Daily uncertainty | | | 1 class | 9060 | | | | | Pt100 | IEC | [-100 °C; +100 C]: C | C | | Class B | 60751 | | | WS | | Class B | | at 0 °C
| |
| Geostationary satellite observations (CAMS) | GHI, DHI, BNI | CAMS | | | Pixel diameter | |
|
|