Research Article

Influence of Inlet and Outlet Area Ratio on Intake Port Flow Capacity

Table 2

Verification result of intake port numerical model.

Pressure different (kPa)Valve lift (mm)Discharge coefficients
Test resultNumerical resultError (%)

520.2010.2177.96
30.2930.3147.17
40.3910.4115.12
50.4530.4744.55
60.5280.5575.45
70.6010.6315.04
80.7120.7414.05

Note: .