Research Article

Modeling Gas Compressor Station Operation to Minimize Fuel Costs for Surge Zone Protection

Table 3

Main design characteristics of the workload (Mon, Feb 01, 2021, 02:00:00).
(a) R valve closed

Calculated rotations5035rot/min
Real rotations5000rot/min
0.9401
0.6676
calculated13.3783°C
real15°C
124.671
4887.5kW
2495.96kW
0.5629
1.8642
2751.13kW
1557.31m3/hour
Compressor work point X249.677
Compressor work point Y1.1265

(b) R valve opened—recirculation

Calculated rotations5107rot/min
Real rotations5000rot/min
0.9535
0.6245
calculated14.108°C
real15°C
123.945
4887.5kW
2588.72kW
0.5838
1.8925
2853.37kW
1596.53m3/hour
Compressor work point X257.073
Compressor work point Y1.1265