Research Article
Numerical Analysis of Pool Fires in Oil Trunkline Networks
Table 1
Comparison of full-scale measurements and results of numerical simulation of an isooctane fire.
| Parameter | Experiment | Numerical calculation | , % |
| Fire length , | 0.115 | 0.128 | 10.2 | Fire width at a level of from the liquid surface, | 0.032 | 0.026 | 23.1 | Angle of fire vertical deviation under a wind of , radian | 0.1651 | 0.2765 | 40.3 |
|
|