Research Article

Numerical Analysis of Pool Fires in Oil Trunkline Networks

Table 1

Comparison of full-scale measurements and results of numerical simulation of an isooctane fire.

ParameterExperimentNumerical calculation m 2 , %

Fire length m 2 , m 0.1150.12810.2
Fire width m at a level of m from the liquid surface, m 0.0320.02623.1
Angle m / s of fire vertical deviation under a wind of ( 𝐿 = 1 ) , radian0.16510.276540.3