Research Article
A Reduced Order Model for the Design of Oxy-Coal Combustion Systems
Table 6
ROM-predicted outlet gas composition (mole fractions).
| Gas species | OF25 | OF50 | OF75 |
| CO | 0.00001 | 0.00679 | 0.04083 | CO2 | 0.85825 | 0.73049 | 0.58303 | H | 0.0 | 0.00005 | 0.00090 | HO2 | 0.0 | 0.0 | 0.00001 | H2 | 0.0 | 0.00036 | 0.00293 | H2O | 0.10550 | 0.19008 | 0.24832 | NO | 0.00001 | 0.00026 | 0.00077 | N2 | 0.00117 | 0.00202 | 0.00252 | O | 0.0 | 0.00029 | 0.00289 | OH | 0.00003 | 0.00336 | 0.01566 | O2 | 0.03463 | 0.06556 | 0.10116 | SO | 0.0 | 0.0 | 0.00001 | SO2 | 0.00040 | 0.00073 | 0.00097 |
|
|