Journal of Energy / 2016 / Article / Tab 1 / Research Article
A Thermodynamic Analysis of Two Competing Mid-Sized Oxyfuel Combustion Combined Cycles Table 1 Cycle performance for the SCOC-CC from earlier papers.
Paper Year ASU kW/(kg/s) Output MW TIT °C PR %[4 ] 1992 1512 514.7 30 41.4 [5 ] 1997 1200 48 47.26 [6 ] 1998 193 1376 56 36.7 [8 ] 1998 900 57.2 1319 30 44.9 [37 ] 2003 1440 250 35 47.2 [30 ] 2004 972 400 1328 44.1 [32 ] 2007 812 400 1328 47 [33 ] 2008 1225 400 1400 40 49.75 [15 ] 2009 329.7 1232 40 48.3 [9 ] 2009 861 396 1427 24.5 51.3 [10 ] 2010 475.7 1400 40 53.9 [35 ] 2012 1225 106 1400 37 46 [16 ] 2012 1021 291.1 1418 60 48.2 [16 ] 2012 473.8 1600 90 52.2 [17 ] 2013 735 125 1340 34 47.21
Delivery pressure from ASU is the operating pressure. Delivery pressure from ASU is 1 bar. Delivery pressure from ASU is 27 bar. Delivery pressure from ASU is 1.2 bar.