Research Article

The Technical and Economic Study of Solar-Wind Hybrid Energy System in Coastal Area of Chittagong, Bangladesh

Table 12

COE of different system configurations with 3 different multipliers.

System Capital multiplier COE ($)

Grid/wind 1 0.129
0.8 0.112
0.6 0.096

Grid/PV/wind/inverter 1 0.145
0.8 0.127
0.6 0.109

Grid/PV/battery/inverter
(5 kW PV, 22 kW inverter)
1 0.173
0.8 0.171
0.6 0.17

Grid/PV/wind/battery/inverter 1 0.192
0.8 0.174
0.6 0.156

PV/wind/battery/inverter 1 0.292
0.8 0.254
0.6 0.215