Research Article
Effect of Parametric Uncertainties, Variations, and Tolerances on Thermohydraulic Performance of Flat Plate Solar Air Heater
Table 3
Effect of change of solar insolation
on thermal and effective efficiencies (
= 2 m,
= 10 mm, and
= 1 m).
| (kgs−1m−2) | Baseline value | |
Winter ( = 285 K, = 12 Wm−2K−1, = 40°) |
Summer ( = 310 K, = 15 Wm−2K−1, = 0°) | (Wm−2) | (%) | (%) | (Wm−2) | (%) | (%) |
| 0.01 | 800 | 0.95 | 500 1000 | 0.7 −1.04 | 0.63 −1.03 | 500 1000 | 1.64 −1.31 | 1.64 −1.25 | 0.06 | 800 | 0.95 | 500 1000 | −1.69 0.48 | −8.1 2.4 | 500 1000 | −0.74 0.14 | −8.43 2.46 | 0.01 | 800 | 0.1 | 500 1000 | 0.98 −0.68 | 0.94 −0.64 | 500 1000 | 1.88 −0.99 | 1.8 −0.98 | 0.06 | 800 | 0.1 | 500 1000 | −0.67 0.14 | −6.27 1.87 | 500 1000 | −0.06 0.01 | −6.77 1.42 |
|
|