Research Article

Applying Energy-Dispersive X-Ray Fluorescence Analysis to Detect Tungsten Inclusions in Nuclear Fuel Rod End Plug TIG Welds

Table 3

Results of the simulation.

Zr depth (mm)W diameter(mm)

00.04
0.10.05
0.20.06
0.30.08
0.40.10
0.50.12
0.60.14
0.70.20