Table 6

Diagnostic performance of microscopy and SD-bioline RDT using nested PCR as reference standard.

TFMSD-bioline RDT

TP (nPCR = 112)849
FP (nPCR = negative)112
TN (nPCR = 115)115115
FN (nPCR = positive)10351
Sensitivity (95% CL)7.21% (3.16–13.71%)49.00% (38.86–59.20%)
Specificity (95% CL)99.14% (95.29–99.98%)90.55% (84.08–95.02%)
PPV (95% CL)88.89% (50.49–98.44%)80.33% (69.69–87.88%)
NPV (95% CL)52.75% (51.39–54.11%)69.28% (64.86–73.37%)
Accuracy (95% CL)54.19% (47.46–60.79%)72.25% (65.94–77.97%)
Cohen’s kappa value0.0640.431