Research Article
Real-Time Frequency-Tracking Method Based on Interpolated Kalman Filter Using Vibration and Surface Noise
Table 1
Frequency measurement accuracy of signals generated by the standard vibration exciter (Hz).
| Frequency | FFT | KF | WT | SDFT | IKF | Frequency | FFT | KF | WT | SDFT | IKF |
| 20 | 0 | 0 | 1.0E-1 | 1.0E-3 | 1.5E-3 | 20.2 | 0.2 | 0.2 | 8.0E-3 | 1.1E-3 | 2.3E-3 | 30 | 0 | 0 | 8.6E-2 | 3.2E-3 | 3.1E-3 | 30.3 | 0.3 | 0.3 | 1.7E-2 | 3.3E-3 | 4.4E-3 | 40 | 0 | 0 | 2.5E-1 | 2.9E-3 | 6.4E-3 | 40.7 | 0.7 | 0.7 | 3.7E-2 | 4.8E-3 | 7.2E-3 | 50 | 0 | 0 | 7.1E-2 | 6.7E-3 | 7.3E-3 | 52.3 | 0.3 | 0.3 | 6.5E-1 | 6.1E-3 | 7.9E-3 | 60 | 0 | 0 | 3.1E-1 | 8.3E-3 | 8.1E-3 | 61.3 | 0.7 | 1.3 | 4.6E-2 | 8.8E-3 | 9.2E-3 | 75 | 1 | 1 | 9.4E-2 | 7.9E-3 | 8.8E-3 | 75.3 | 0.7 | 1.3 | 2.2E-1 | 8.9E-3 | 9.9E-3 | 80 | 0 | 0 | 4.4E-1 | 7.1E-3 | 8.9E-3 | 80.3 | 0.3 | 0.3 | 7.0E-1 | 1.0E-3 | 1.1E-2 | 97 | 1 | 1 | 5.2E-1 | 8.8E-3 | 9.8E-3 | 97.7 | 0.3 | 1.7 | 8.3E-2 | 9.9E-3 | 1.1E-2 | 100 | 0 | 0 | 4.9E-1 | 9.6E-3 | 9.5E-3 | 102.7 | 0.7 | 0.7 | 5.3E-1 | 1.2E-2 | 1.2E-2 | 120 | 0 | 0 | 6.9E-1 | 9.9E-3 | 9.9E-3 | 122.3 | 0.3 | 0.3 | 7.5E-2 | 1.2E-2 | 1.2E-2 |
|
|