Research Article

A Digital Controller for Reactivity Monitoring and Power Control

Table 2

Maximum value of the measured reactivity when withdrawing the AR rod from 367 mm to 310 mm.

Reactor power rangePower level changed (% Pnom)AR rod position (mm)Reactivity value in logbook (pcm)Reactivity by BNO-102R1 (pcm)Reactivity by FPGA-controller (pcm)

Starting4 × 10−3 to 6 × 10−3367 to 31053.4 ± 0.05%53.1 ± 5%52.7 ± 5%
Working5 × 10−1 to 2.35369 to 310N/A72.1 ± 5%71.5 ± 5%